Overview
YSG inductive pressure (micro) transmitter is mainly forindustrial production processes and measurement systems used to measure avariety of non-crystalline and non-coagulation of steel or iron and its alloyscan not corrode Fluid medium pressure or negative pressure. The instrument cannot only measure the pressure value of the measured medium into a standard DCsignal, in order to facilitate the transmission of measured values over a longdistance, and ultimately in the central control room with the secondaryinstrument to support the production process to achieve automatic detection andcontrol, But also has a mechanical pointer directly to indicate thecharacteristics of pressure values, in order to facilitate on-site inspectionand calibration process.
Main Tech Data
Accuracy:1.6
Voltage YSG-3 Inductive pressure (micro) transmitter YSG-2 Inductive pressure (micro) transmitter
Output DC 24V AC 220V
Load Resistance DC 4~20 mA DC 0~10 mA
Terminals ≤250Ω ≤1KΩ
Weight 1.0 1.3
Secondary instrument XTMA Pressure digital display instrument XTMA Pressure digital display instrument
Ambient: -10 ~ 55 ℃, relative humidity of not morethan 85%.
Temperature effect: Temperature deviationfrom 20 ± 5 ℃, the temperature of the additionalerror not more than 0.75% / 10 ℃.
Model YSG-2.3
Measure range 0~0.060~0.10~0.160~0.250~0.40~0.60~10~1.60~2.50~40~60~100~160~250~400~60 -0.1~0 0.1~0.060.1~0.15-0.1~0.3-0.1~0.5-0.1~0.9-0.1~1.5-0.1~2.4 MPa
Structural principle
The instrument consists of two parts: one is the mechanicalpointer to indicate the pressure gauge; the other is the conversion part andthe electronic amplifier. The former consists of a measuring system driveindicating part and a shell part. The cover of the instrument is a splash-proof structure with good sealing, so it can protect the internal mechanism frommechanical damage and contamination. The latter includes displacement-inductive converters and electronic amplifiers. Amplifier parts with room temperaturevulcanized silicone rubber dip surface, it has a good corrosion resistance andmoisture resistance.
Express Lane
- CATEGORIES:
XFJ Automatic balance recorder EJ Automatic balance recording adjustment alarm EH Automatic balance recording adjustment alarm LKB Flow controller Flow controller WTZK Temperature controller D541 Temperature controller D540 Temperature controller Temperature controller D520 Pressure drop controller D530 Pressure drop controller Pressure drop controller