|
Overview:
PM10pressure transmitter is made by the technology from UK, which is suitable forindustrial processes to measure the pressure of a variety of fluid media, thepressure parameters into two-wire 4 ~ 20mA DC standard DC signal output, inorder to facilitate the corresponding display and support the function of thepressure to achieve automatic detection and control.
PM10/IP68 submersible pressure transmitter can beused as an input level gauge.
PM10/LCD liquid crystal display pressure transmitter isa two-wire 4 ~ 20mA DC current output signal and can display the pressure valueof the transmitter, three and a half display, display accuracy of 0.5, thepower supply voltage 17~36V DC
In theordinary type of pressure transmitter on the basis of the development of avariety of extended products, such as mercury-filled diaphragm-typehigh-temperature melt pressure transmitter, with heat pipe transmitter and soon.
Features
Highprecision 0.15, 0.3 Grade
Measuringrange: 10Kpa to 60Mpa surface pressure and absolute pressure
Vibrationresistance, anti-radio frequency electromagnetic interference
Anti-overloadand impact resistance
Thecontact media part is Hastelloy and stainless steel
Ultra-small,resistant to moisture, easy to install
Two-wire(4 ~ 20mA) output signal
Varioustypes of electrical and pressure interfaces are available
Canprovide input level gauge; intrinsically safe; marine type.
Main tech of PM10-CB
Measurerange
Surfacepressure:0~10Kpa to 0~60Kpa
Absolute pressure:0~25Kpa to 0~1Mpa
Output:two wires 4~20mA
Powersupply:9~30V DC
Measurerange and Zero:±5% of full range
Environment:
Temperature:
A. Amplifier-20~+80℃
B. Silicon strain diaphragm working temperature -30 ~ +120 ℃
C. Transmitter storage temperature -40 ~+125 ℃
Humidity:relative humidity 0 to 100%
Volumechange: not more than 2.5px3
Accuracyclass: 0.3 (0.15) *
Repeatability: Better than full scale range of 0.15% (0.075%)
Resistanceto overload capacity: 60Kpa the following range:0.2Mpa
4Mpa or higher: 2 times the range
Anti-RFinterference: can withstand electromagneticinterference flow for the frequency of 30KHz ~ 200MHz; interference intensity:1V / mm radio frequency interference
Temperatureeffects: the use of ambient temperature, such asdeviation from 20 ± 20 ℃ when thetemperature should be considered
Additionalerror K: range greater than 1 Mpa K is 0.3% / 10 ℃ (0.15% / 10 ℃)
The range is less than 60 Mpa K is 0.6% /10 ° C (0.3% / 10 ° C)
Vibrationeffects: can be used in vibration frequency 2 ~25Hz, displacement amplitude ± 1.6mm and vibration frequency 25 ~ 100Hz,acceleration amplitude ± 40m / s environment.
Powersupply effects: less than full range of 0.005% / V
Loadeffect: less than full scale of 0.01% / 100Ω
Mountingposition effects: Transmitters with a range of lessthan 60Kpa, the zero position may have a slight change, which can be eliminatedby a zero adjustment potentiometer.
Weight: body 0.4 kg
Express Lane
- CATEGORIES:
Turbine flowmeter Accessries High performance butterfly valve Pneumatic butterfly control valve Pneumatic soft seal butterfly valve Pneumatic segment ball valve Pneumatic ball valve Pneumatic diaphragm control valve Pneumatic lining valve Pneumatic three-way valve Pneumatic single seat control valve Bellows seal control valve