Overview:
PM10pressure transmitter is made by the technology from UK, which is suitable forindustrial processes to measure the pressure of a variety of fluid media, thepressure parameters into two-wire 4 ~ 20mA DC standard DC signal output, inorder to facilitate the corresponding display and support the function of thepressure to achieve automatic detection and control.
PM10/IP68 submersible pressure transmitter can be used as an input level gauge.
PM10/LCD liquid crystal display pressure transmitter is a two-wire 4 ~ 20mA DC currentoutput signal and can display the pressure value of the transmitter, three anda half display, display accuracy of 0.5, the power supply voltage 17~36V DC
In theordinary type of pressure transmitter on the basis of the development of avariety of extended products, such as mercury-filled diaphragm-typehigh-temperature melt pressure transmitter, with heat pipe transmitter and soon.
Features
Highprecision 0.15, 0.3 Grade
Measuringrange: 10Kpa to 60Mpa surface pressure and absolute pressure
Vibrationresistance, anti-radio frequency electromagnetic interference
Anti-overloadand impact resistance
Thecontact media part is Hastelloy and stainless steel
Ultra-small,resistant to moisture, easy to install
Two-wire(4 ~ 20mA) output signal
Varioustypes of electrical and pressure interfaces are available
Canprovide input level gauge; intrinsically safe; marine type.
Main tech of PM10
Measurerange
Surfacepressure:0~10Kpa to 0~60Kpa
Absolute pressure:0~25Kpa to 0~1Mpa
Output:two wires 4~20mA
Powersupply:9~30V DC
Measurerange and Zero:±5% of full range
Environment:
Temperature:
A. Amplifier-20~+80℃
B. Silicon strain diaphragm working temperature -30 ~ +120 ℃
C. Transmitter storage temperature -40 ~+125 ℃
Humidity:relative humidity 0 to 100%
Volumechange: not more than 2.5px3
Accuracyclass: 0.3 (0.15) *
Repeatability: Better than full scale range of 0.15% (0.075%)
Resistanceto overload capacity: 60Kpa the following range:0.2Mpa
4Mpa or higher: 2 times the range
Anti-RFinterference: can withstand electromagneticinterference flow for the frequency of 30KHz ~ 200MHz; interference intensity:1V / mm radio frequency interference
Temperatureeffects: the use of ambient temperature, such asdeviation from 20 ± 20 ℃ when thetemperature should be considered
Additionalerror K: range greater than 1 Mpa K is 0.3% / 10 ℃ (0.15% / 10 ℃)
The range is less than 60 Mpa K is 0.6% /10 ° C (0.3% / 10 ° C)
Vibrationeffects: can be used in vibration frequency 2 ~25Hz, displacement amplitude ± 1.6mm and vibration frequency 25 ~ 100Hz,acceleration amplitude ± 40m / s environment.
Powersupply effects: less than full range of 0.005% / V
Loadeffect: less than full scale of 0.01% / 100Ω
Mountingposition effects: Transmitters with a range of lessthan 60Kpa, the zero position may have a slight change, which can be eliminatedby a zero adjustment potentiometer.
Weight: body 0.4 kg