EH100-12 EH200-12 EH800-12 EH900-12 EH Automatic balance recording adjustment alarm
1、 Product introduction of EH100-12 EH200-12 EH800-12 EH900-12 EH Automatic balance recording adjustment alarm
H series 180mm recorder is a highly reliable recorder produced by using information accumulated for many years and introducing the latest electronic technology and precision machinery.
There are more than 900 models for selection according to various combinations. The recording methods include single pen, double pen and three pen writing, and line punctuation from 6 to 12 o'clock and 24 o'clock; The adjustment modes include 2-position, 3-position and PID; The alarm modes include upper limit type, lower limit type and upper and lower limit type. With these combinations, we can provide the high-quality recorders that our supporters are eagerly looking forward to. It is used for all temperature, pressure flow, meteorological observation, measurement and control.
2、 Product features of EH100-12 EH200-12 EH800-12 EH900-12 EH Automatic balance recording adjustment alarm
High accuracy: the accuracy of industrial recorder is ± 0.5%. With the latest electronic technology and high reliability design, it can provide products with indication accuracy of ± 0.25% of the input range according to the needs of users. The highest accuracy is obtained in the industrial recorder.
Long life: high resolution, long life balance sliding wire resistor
High reliability: good sealing, high reliability input switch
Readability: install standard lighting
Clear record: clear record curve of critical damping
Adaptability: a wide range of choices
Simple maintenance: unit structure easy to maintain
Flexible operation: firm structure and convenient front operation
3、 Technical parameters
Input signal: above mv-dc3mv, thermoelectric group above -30 ℃ (PT100)
Scale length: 180mm
Indication accuracy: ± 0.5% of input range
Indication return difference: 0.25% of input range
Balance time: input range moves about 2S (50Hz)
Recording paper: folding - effective recording 180mm (full width 200mm), total length 20m
Pen writing - single pen, double pen and three pen
Punctuation - 6:00, 12:00 and 24:00
Pen writing type: continuous recording with fiber pen; 1st (red), 2nd (green), 3rd (blue)
Dot type: dot record of each dot dipped in inkpad
Dot: 6 dots: 1 red, 2 black, 3 sky blue, 4 green, 5 brown, 6 Purple
12 points: 1 red, 2 black, 3 sky blue, 4 green, 5 brown, 6 purple, 7 orange, 8 gray, 9 blue, 10 grass green, 11 peach red, 12 red
24 point repeat 12 point and 1~24 point digital printing
Paper feeding speed: 12.5, 25, 50, 100mm/h4 speed and fast
Dotting time: 6S (50Hz), 5S (60Hz)
Recording pen interval: About 4mm (when there are multiple pens)
Lifting and dropping pen (pen type): manual, each pen is independent
Power supply: AC220V 50Hz
Allowable voltage variation: 10%~15% of rated value
Ambient temperature: 0 ℃ ~50 ℃
Relative humidity: 10%~90%rh
Allowable signal source resistance:
DC voltage input - 3MV < range voltage ≤ 500mv-10k Ω
500mv < range voltage ≤ 100mv-10k Ω
Thermocouple Input below -10k Ω
Thermocouple Input - less than 10 Ω per wire
Input resistance: DC voltage input - 3MV ≤ range voltage ≤ 500mv- about 8m Ω
500mv < range voltage ≤ 100mv- about 1m Ω
Thermocouple Input - approx. 8 Ω
Insulation resistance: DC500v above 20m Ω between the measuring terminal and the grounding terminal
DC1000V above 20m Ω between power terminal and grounding terminal
DC1000V above 20m Ω between measuring terminal and power terminal
Insulation strength: Ac500V between measuring terminal and grounding terminal for 1min
AC1000V (100V series power supply) 1min between power supply terminal and grounding terminal
Ac1500v (200V series power supply) 1min
AC1000V (100V series power supply) between measuring terminal and power supply terminal for 1min
Ac1500v (200V series power supply) 1min
Lighting lamp: fluorescent lamp (but the 24-point instrument has no lighting)
Power consumption: About 35W
Door: aluminum die casting, painted black palladium
Shell: ordinary steel plate painted silver gray
Installation method: panel mounted - only the installation angle of dot type instrument can be tilted back by 30 ℃
Express Lane
- CATEGORIES:
Turbine flowmeter Accessries High performance butterfly valve Pneumatic butterfly control valve Pneumatic soft seal butterfly valve Pneumatic segment ball valve Pneumatic ball valve Pneumatic diaphragm control valve Pneumatic lining valve Pneumatic three-way valve Pneumatic single seat control valve Bellows seal control valve