Brief Description
The Y-100A/Z/MF(B)/316 diaphragm seal pressuregauge applicable to medium which are strong corrosive, high-temperature,high-viscosity, easy to crystallize & solidify, and with suspended solid,also to avoid direct contact between general pressure gauge and medium, to makegauge easy to wash, we combine diaphragm isolator with general pressure gauge,which is a diaphragm-seal pressure gauge. Diaphragm-seal pressure gauge ismainly used in petrochemical industry, alkali-making, chemical fiber, dyeing,pharmacy, and food industries to measure medium pressure.
Technical Parameters
Accuracy: 2.5%, 1.6%
Ranges (MPa):-0.1~0;-0.1~0.06;-0.1~0.15;-0.1~0.3;-0.1~0.5;-0.1~0.9;-0.1~1.5;-0.1~2.4;0~0.1;0~0.16;0~0.25;0~0.4;0~0.6;0~1.0;0~1.6;0~2.5;0~4;0~6;0~10;0~16;0~25;0~40;0~60;
Working pressure: dead load is up to 3/4 of upper limit;stress alternating is up to 2/3 of upper limit; instant pressure is up to upperlimit.
Working environment temperature: -40~70℃ (relative humidity isnot more than 85%)
Temperature influence: when working temperature deviationis 20±5℃, the errorchange is not more than 0.6%/10℃.
Pressure measuring element: double capsule
Case: stainless steel
Scale: stainless steel
Needle: aluminum, black
Gauge glass: common glass
Connection: flange type, thread connection
Gauge is with micro zero-adjusting device
Note:If you have special requirement of Y-100A/Z/MF(B)/316 diaphragm sealpressure gauge,feel free to contact us.
Express Lane
- CATEGORIES:
XBJ Automatic balance recorder XCJ Automatic balance recorder XGJ Automatic balance recorder XFJ Automatic balance recorder EJ Automatic balance recording adjustment alarm EH Automatic balance recording adjustment alarm LKB Flow controller Flow controller WTZK Temperature controller D541 Temperature controller D540 Temperature controller Temperature controller