WZP assembly type RTD (PT100)
Brief Description
The WZC-130 assembly type RTD (PT100) produced by shanghai automation is usedwith displayer, recorder and electrical adjuster completely. It can measure thetemperature of liquid, vapor, gas and the surface of solid from -200℃ to 420℃ directly. Per nationalregulation, we have manufactured PT100 platinum resistance thermometer in lineof IEC international standard graduation and CU50 copper resistance in line ofprofessional graduation since 1987.
Type °C Range Graduation Allowed deviation Δ°C
WZP Platinum resistance ﹣200-420 Pt100 B(0.30+0.005|t|)
A(0.15+0.002t)
WZC copper resistance -150~100 Cu50 -50~150℃±(0.30+6.0×10-3t)
Models
W Temperature meter
Z Resistance thermometer
Resistor material P)platinum resistance
install and fixed type 1)Without fixed device type2)fixed thread type3)movable flange4)fixed flange type6)fixed thread taper protect tube type
junction box type 2)splash proof type3)waterproof typeUn-standard:socket mount type,small junction box type and so on
design series number 0)ø16mm protecting tube1)ø12mm protecting tubeUn-standard:all sizes of protecting tubes
RTD (PT100) without fixed device
Type Model Graduation Range Tube Material d mm Response time
Simplex type WZP-120 Pt100 -20~420 1Cr18Ni9Ti0Cr18Ni12M02Ti φ16 ≤90
WZP-121 φ12 ≤30
WZP-130 φ16 ≤90
WZP-131 φ12 ≤30
Duplex type WZP2-120 φ16 ≤90
WZP2-121 φ12 ≤45
WZP2-130 φ16 ≤90
WZP2-131 φ12 ≤45
copper resistance WZC-120 Cu50 -50~100 Brass H621Cr18Ni9Ti φ12 ≤120
WZC-130
Note: For special requirement of the WZC-130 assembly type RTD (PT100), please contact themanufacturer.