WSS Series BimetalThermometer
Brief Description
The WSS-522 bimetallicthermometer is used to measure field middle and low temperature, can be used tomeasure directly the temperature of liquid and gas. Compared with glass mercurythermometer, it has no mercury harm, easy to read, strong and durable. The protectiontube, joint and locking bolt of WSS series bimetallic thermometer are1cr18ni9ti stainless steel, the case is made of stretched aluminum board aftermachining, surface is dealt with electrophoresis processing, the head (coverand box) is ring type double rubber ring seal locking structure, thus thewaterproof & anti-corrosion performance is good, radial (straight) typeadopts bend tube structure, novel appearance, light, beautiful and unique.
Technical Parameters
Temperature range: 60-500 ℃
Accuracy: 1.5.Contactor action error limit is 1.5tiims of readings basic error. .
Thermometer dial diameter: 60, 100, 150mm.
Tube length: 75-2000mm.
Tube diameter: 6, 8, 10 (when tube length is 100-1250); 12(when tube length 1250-2000mm).
Install thread: M16X1.5, M27X2, G1/2, G3/4, tube and fixedbolt joint are1 cr18ni9ti stainless steel, pressure 6.4 MPa.
Working voltage should be between 15V and 48V.
Waterproof performance: the shell can withstand spray from 25mm-faucet5m away (water pressure is not less than 2Kg/m2),no water penetrate the thermometer case within 5minitues.
Housing: IP65
Contact rated power: 10 VA
Contact maximum operatingvoltage: ~ 380 v or 220 v
Contact maximum workingcurrent: 1a (non-inductive load)
Model
W S S specification
-
3 ø60
4 Ø100
5 Ø150
Dial nominal diameter 0 Angle or axial type
1 Straight or radial type
8 Universal type
5 Angle type with hot jacket
6 Straight type with hot jacket
7 Universal type with hot jacket
structural style 1 Movable male thread
2 Movable female thread
3 Movable Flange
Mounting type
W S S □ - □ □ □
Note: For special requirement of the WSS-522 bimetal thermometer, please contactthe manufacturer.