Brief Description
The WRE-230-F anti-corrosion thermocoupleis a temperature detector widely used in sea water, various of chlorides andhypochlorite, wet chlorine and oxidizing acids (including fuming nitric acid)and so on. The special structure and material thermocouple has to be used inspecial occasions, such as chemical plant, power plant, Smelter and so on. Anti-corrosionthermocouple includes type K and E. Thethermocouple conforms to JB/T9238-1999 and JB/T8622-1997.
Name Graduation Measure range(℃) Allowed Deviation △t(℃)
Nickel chromium-nickel silicon K 0~600 ±2.5℃ or±0.0075∣t∣
Nickel chromium-copper nickel E
Othertechnical indicators conform to JB / T9238-1999 industrial thermocoupletechnical conditions and JB / T8622-1997 technical conditions.
Modelof WRE-230-F anti-corrosionthermocouple
Anti-corrosion thermocouple
Name Graduation Coating Measure range(℃) Tube d Spec
WRN-130-FWRN-230-FWRN-330-FWRN-430-F K F 0~250 16+2 300×150350×200400×250450×300550×400650×500900×7501150×10001650×1500
WRN2-130-FWRN2-230-FWRN2-330-FWRN2-430-F TC 0~250
WRE-130-FWRE-230-FWRE-330-FWRE-430-F E
WRE2-130-FWRE2-230-FWRE2-330-FWRE2-430-F T 0~500 16