Brief Description
The WRE-120 assembly thermocouple is used as a sensor tomeasure temperature, usually matched with display instruments, recording meterand electronic regulator. It can directly measure temperature from 0oCto 1800oC of liquid, vapor, gas medium and solid surface duringvarious production processes.
Since 1987,according to the national regulations, our factory have been producing thermocouplemade from PtRh30-PtRh6, PtRh10, NiCr-NiSi, NiCr-CuNi, Cu-CuNi, Fe-CuNi etc underthe IEC international standard index numbers, and JB/T9238-1 999 standard aswell.
Category Model Graduation Range Allowable error(△t℃)
Platinum rhodium30-Platinum rhodium6 WRR B 0-1800 ±1.5℃ or ±0.0025∣t∣
Platinum rhodium10-platinum WRP S 0-1600 ±1.5℃ or ±0.0025∣t∣
Nickel chromium-nickel silicon WRN K 0-1300 ±2.5℃ or ±0.0075∣t∣
Nickel chromium-copper nickel WRE E 0-800 ±2.5℃ or ±0.0075∣t∣
Model of WRE-120 assembly thermocouple
W Temperature meter
R Thermocouple
□thermocouple material R) Platinum rhodium30-Platinum rhodium6
P) Platinum rhodium10-platinum
N) Nickel chromium-nickel silicon
E) Nickel chromium-copper nickel
□ install and fixed type 1) without fixed device
2)fixed thread type
3)movable flange type
4)fixed flange type
5)movable flange with square tube type
6) fixed thread with tapered tube type
□ junction box type 2)splash proof type
3)waterproof type
4)explosion-proof type
□ design series number 0)ø16mm protecting tube
1)ø25mm protecting tube(double tubes)
2)ø16mm high aluminum tube(single tube)
3)ø20mm high aluminum tube
Upper and lower limits of thermocouple and insulatingresistance:
Upper temperature limit(tm℃) Test temperature(T℃ ) Resistance(MΩ)
100≤tm<300 t=tm 10
300≤tm<500 t=tm 2
500≤tm<850 t=tm 0.5
850≤tm<1000 t=tm 0.08
1000≤tm<1300 t=tm 0.02
tm>1300 t=1300 0.02
Thermocouple without fixed device
Thermocouple Model Graduation Temp range℃ Protection tube material Specs Junction box type
Total length L mm
Simplex NiCr-NiSi WRN-120 K 0~800 0~1000 1Cr18Ni9Ti 1Cr25Ni20# 300350400450550650900115016502150 Splash-proof type
Duplex Nicr-NiSi WRN2-120
Single NiCr-CuNi WRE-120 E 0~600 1Cr18Ni9Ti
Duplex NiCr-CuNi WRE2-120
Simplex NiCr-NiSi WRN-130 K 0~8000~1000 1Cr18Ni9Ti1Cr25Ni20# Water-proof type
Duplex NiCr-NiSi WRN2-130
Simplex NiCr-CuNi WRE-130 E 0~600 1Cr18Ni9Ti
Duplex NiCr-CuNi WRE2-130
Note 1) Thermal-responsetime-T0.5<90seconds
2) “#” means there has nosuch type material
Note: For specialrequirement of the WRE-120 thermocouple, please contact themanufacturer.