Brief Description
The WRE-010 thermocouple element is used as a replacement of sensorto measure temperature, usually matched with display instruments, recordingmeter and electronic regulator. It can directly measure temperature from 0oCto 1800oC of liquid, vapor, gas medium and solid surface duringvarious production processes.
Main tech data
Temperature measure range
Category Model Graduation Range Allowable error(△t℃)
Platinum rhodium30-Platinum rhodium6 WRR B 0-1800 ±1.5℃ or ±0.0025∣t∣
Platinum rhodium10-platinum WRP S 0-1600 ±1.5℃ or ±0.0025∣t∣
Nickel chromium-nickel silicon WRN K 0-1300 ±2.5℃ or ±0.0075∣t∣
Nickel chromium-copper nickel WRE E 0-800 ±2.5℃ or ±0.0075∣t∣
Note“t”means the actual measuringtemperature
Thermocouple element
Type Model Graduation Measure range℃ Diameterd mm Total L mm
NiCr-NiSi WRN-010 K(EU-2)﹡ 0~1000 Φ11 300350400450550650900115016502150
NiCr-CuNi WRE-010 E(EA-2)﹡ 0~600
PtRh30-PtRh6 WRR-010 B(LL-2)﹡ 0~1600 Φ8
PtRh30-PtRh6 WRR2-010
PtRh10-Pt WRP-010 S(LB-3)﹡ 0~1300
PtRh10-Pt WRP2-010
PtRh10-Pt WRP-100 S(LB-3)﹡ 0~1300 252 225
Note: For special requirement of the WRE-010 thermocouple element,please contact the manufacturer.
Express Lane
- CATEGORIES:
HAL Hall speed sensor SZGB Photoelectric speed sensor SZMB Magnetic speed sensor Speed sensor SZJ standard speed generator XBJ Automatic balance recorder XCJ Automatic balance recorder XGJ Automatic balance recorder XFJ Automatic balance recorder EJ Automatic balance recording adjustment alarm EH Automatic balance recording adjustment alarm LKB Flow controller