D502/7D Ex Proof pressurecontroller
Descriptionof 0851880 D502/7D Ex proofPressure controller 0.05-2.5MPa:
The 0851880 D502/7D Ex proof Pressure controller0.05-2.5MPa usesbellows type sensors, which can be used in air, gas, water vapor and otherneutral gas and water, refrigerant, oil and other liquid media. The settingvalue of the controller is adjustable. Range of adjustment -0.1...... 2.5 Mpa.
Parametersof 0851880 D502/7D Ex proofPressure controller 0.05-2.5MPa:
Working: <1×10-3m2/s
Element: Micro Switch
Ex Grade: ExdeⅡCT5
Enclosure: IP54
Ambient: -5~40℃
Medium temp: 0~120℃
Installation: Pull interface vertical downward
Vibration: Max:20m/s2
Repeatability: ≤1%
Contact: DC 250V 0.25A(Resistance)60 Wmax
AC 250V 5A(Resistance) 1250VAmax
Express Lane
- CATEGORIES:
Marine diaphragm pressure controller radio frequency admittance Level Controller Rotary paddle level gauge Float level controller Level Transmitter Electric float level transmitter Radar level meter Ultrasonic level meter Glass plate level meter Glass tube level meter Float level gauge Magnetic level gauge